Multiple valve controller 503

Model:JMA503
Price:0US$
Multiple valve controller Functions:
◆ Password setting
◆ Calendar
◆ Regeneration stage and regeneration time indication
◆ JMA can be initiated manually or through remote control. Timer initiation and interval initiation are also
 Details


Multiple valve controller


JMA stager controller

Multiple valve controller_ JMA stager controller_Multi-valve system controller

Multiple valve controller Introduction

Multiple valve controller functions:
◆ Password setting
◆ Calendar
◆ Regeneration stage and regeneration time indication
◆ JMA can be initiated manually or through remote control. Timer initiation and interval initiation are also

Multiple valve controller available.
◆ Manual step by step initiation (only for system commissioning)
◆ Reset function
◆ Stages (1-8) and stage duration (5-9999 Sec) settings
◆ System working stage indication (Service or regeneration stage indication)
◆ Data protection after power cut: settings and data can be stored for 3 years.
◆ Waterproof and rotproof enclosure

JMA stager controllerMultiple valve controller
working principle:
The stager may be manually operated or driven by an electric motor that operated through an adjustable timer or flowmeter program. The stager functions by opening and closing its ports, singly or in combination, in a sequence that fit the need of the system. The “positions” in the sequence correspond to the number of “stager” in the process (See chart 1). The port that are opened allow the pressurized fluid to flow to and operate some diaphragm valves, while venting other valves—allowing them to return to their normal positions.
The stagers can use either hydraulic or pneumatic control fluid. Continuous electrical power is not required to maintain the positions of the valves such as in a solenoid operated system. Greatly avoid the system breakdown because of power failure.
All types of complex application can be controlled by stager controller system through correct design and combination of the stagers.

Next is Typical Circuit Application for JMA 502

STAGER POSITION

SOFTENER FUNCTION

VALVES OPEN

4

SERVICE

1, 2

1

BACKWASH

3, 4 (2A)

2

BRINE

5, 2 (2A)

3

FAST RINSE

6, 1 (2A)

JMA stager controller specifications:
◆ Automatic restoration function
◆ Waterproof enclosure (waterproof and shockproof)
◆ Power supply: 220VAC/50HZ
◆ Timer initiation setting: any time of the day 7 days one week
◆ 8 stages available with duration from 5 to 9999 seconds for each stage
◆ Manually initiation
◆ Service/regeneration Light indication
◆ Auxiliary signal output

Multiple valve controller Technical figures:
Electrical supply: 220VAC/50HZ, 10W
Remote control signal: At least 2 seconds/dry contactor
Pressure port size: 1/8”G thread
Control fluid: hydraulic or pneumatic (100μfilter is recommended for the system)
Control fluid pressure: 0.2~0.8MPa
Temperature: 4~60℃
Enclosure size: 270 mm X 170 mm X 105 mm

Multiple valve controller Applications:

Item ID

Typical application

Stage program

JMA 501

Filter

Service→backwash→rinse

JMA 502

Co-current regeneration softener

Service→backwash→brine + slow wash→rinse

JMA 503

Filter

service→backwash

JMA 505

Counter-current regeneration softener

Service→backwash→brine + slow wash→rinse

JMA 506

3 tanks filter

service→1#backwash→2#backwash→3#backwash

JMA 507

4 tanks filter

service→1#backwash→→→4#backwash

JMA 508

5 tanks filter

service→1#backwash→→→→5#backwash

JMA 523

2 tanks filter (1service 1 stand by )

1#service→1#backwsh→2#service→2#backwash

JMA 524

Co-current regeneration water softener

service→backwash→brine→slow wash→rinse→refill

JMA 525

Co-current regeneration water softener

service→backwash→brine→slow wash→rinse

JMA 526

Co-current regeneration water softener

service→backwash→brine→rinse→refill

JMA 527

2 tanks parallel filter

service→backwash 1→rinse 1→backwash 2→rinse 2

JMA 528

Filter

service→drain→air flush→backwash→rinse

JMA 529

Brine recycle water softener

service→backwash→brine→brine+slow wash→brine recycle →rinse

JMA 530

6 tanks filter

service→1#backwash→→→→6#backwash

JMA 531

7tanks filter

service→1#backwash→→→→7#backwash



 

设为首页 | 加入收藏 | 联系我们   网站地图 广州洁明水处理设备有限公司版权所有 Copyright © 2007-2012 ICP备案号:粤ICP备07067730号-1

关键字链接:玻璃钢罐体 软化水设备 反渗透设备  盘式过滤器 反渗透膜  坎普尔EDI  塞伟尔超滤膜  Y型隔膜阀  阿图祖控制阀  FLECK控制阀  纯水设备  水处理